Digital Display Intelligent Thermostat
  • Digital Display Intelligent Thermostat
  • Digital Display Intelligent Thermostat
  • Digital Display Intelligent Thermostat
  • Digital Display Intelligent Thermostat

Digital Display Intelligent Thermostat

$50.00 - $60.00
Product: Intelligent Temperature Sensor
Output voltage: 12V / 24V / 48V
Temperature control range: -55~110 Degree Celsius
Resolution: 0.1Degree Celsiu (-9.9~99.9Degree Celsius );
Control accuracy: ±0.1 Degree Celsius
Thermostat probe: NTC 3950 / B = 10K 0.5% (waterproof type 1M)
Maximum capacity: 10A
Select
Quantity
Coming soon
Add to cart
More Details

Product: Intelligent Temperature Sensor


Instruction manual:
 
Code    Code Description    Setting Range    Factory settings
P0    Cooling/Heating    C/H    C
P1    Hysteresis setting    0.1-50    2
P2    Max setting value    120    120
P3    Min setting value    -55    -55
P4    Temperature correction    -10.0~10.0Degree Celsius    0
P5    Delay start time    0-10 minutes    0
P6    High temperature alarm    -55~120    Off
P7    Data lock switch    On/off    Off
P8    Restore factory settings    On/off    Off
 
P0:Cooling/Heating mode
High temperature start cooling mode:C
low temperature start heating mode:H

P1:Hysteresis setting
heating mode(H):measured value<=set value - hysteresis start output heated to set value to stop
cooling mode(C):measured value>=set value - hysteresis start output cooled to set value to stop

P2:Max setting value
the setting maximum temperature does not exceed this value

P3:Min setting value
the setting minimum temperature does not lower than this value

P4:Temperature correction
When measuring the temperature and the standard deviation of temperature, you can use this function to correct.Corrected temperature = Temperature before correction + Correction value

P5:Delay start time (minute)

P6:High temperature alarm
When the measured temperature exceed this value,the screen will flash and send out warning beeps,at the same time forced turn off output.

P7:Data lock switch
Turn on the data lock switch,can keep the current setting is not altered.If you need to alter,please turn off the data lock switch.

P8:Restore factory settings
Long press SET button to swith P8,and press SET button again,set to on,then press RST button to restore factory settings.